Overview Indoor: FDU125VH Outdoor: FDCA125VNX-W Backlit Controller: RC-EXZ3A Specifications CAPACITY 12.5 KW Set FDU125AVNXWVH Indoor FDU125VH Outdoor FDCA125VNX-W Power Source (Outdoor Unit) 1 Phase 240V 50Hz *Operation Data Nominal Capacity Range Cooling T1 kW 12.5 (3.5-14.0) Heating H1 14.0 (2.7-17.0) Heating H2 13.10 Power Consumption Cooling T1 3.49 Heating H1 3.61 Max Power Consumption 7.10 Running Current Cooling T1 A 15.3 Heating H1 15.9 Inrush Current, Maximum Current 5, 28 EER Cooling T1 3.58 COP Heating H1 3.88 Sound Power Level (JS C9612) Outdoor dB(A) 70 Sound Pressure Level (JS C9612) Indoor P-Hi:45 Hi:40 Me:34 Lo:29 Outdoor 54 External Dimensions (HXWXD) Indoor mm 280×1370×740 Outdoor 1300x970x370 Net Weight Indoor Kg 54 Outdoor 97 Supply Air Connection mm 170×1200 Return Air Connection 235×1280 External Static Pressure (Max) Pa 200 Airflow Indoor (Cooling) l/s P-Hi:650 Hi:533 Me:433 Lo:333 Indoor (Heating) Refrigerant (Type, Amount, Pre-charge Length) Quantity kg (R32) 4.0 Pre Charged To Pipe Length m 30 Installation Data Refrigerant Piping Liquid Line mm Ø9.52 Gas Line Ø15.88 Connection Method Flare Connection Maximum Pipe Length (One Way) m 100 Max vertical height diff. between O.U. and I.U. 50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 Motion Sensor (Optional) LB-KIT2 Demand response (AS4755) Yes Outdoor air temperature (upper, lower limits) Cooling oC -15 to 50 Heating -20 to 20
Overview Indoor: FDU125VH Outdoor: FDCA125VNX-W Backlit Controller: RC-EXZ3A Specifications CAPACITY 12.5 KW Set FDU125AVNXWVH Indoor FDU125VH Outdoor FDCA125VNX-W Power Source (Outdoor Unit) 1 Phase 240V 50Hz *Operation Data Nominal Capacity Range Cooling T1 kW 12.5 (3.5-14.0) Heating H1 14.0 (2.7-17.0) Heating H2 13.10 Power Consumption Cooling T1 3.49 Heating H1 3.61 Max Power Consumption 7.10 Running Current Cooling T1 A 15.3 Heating H1 15.9 Inrush Current, Maximum Current 5, 28 EER Cooling T1 3.58 COP Heating H1 3.88 Sound Power Level (JS C9612) Outdoor dB(A) 70 Sound Pressure Level (JS C9612) Indoor P-Hi:45 Hi:40 Me:34 Lo:29 Outdoor 54 External Dimensions (HXWXD) Indoor mm 280×1370×740 Outdoor 1300x970x370 Net Weight Indoor Kg 54 Outdoor 97 Supply Air Connection mm 170×1200 Return Air Connection 235×1280 External Static Pressure (Max) Pa 200 Airflow Indoor (Cooling) l/s P-Hi:650 Hi:533 Me:433 Lo:333 Indoor (Heating) Refrigerant (Type, Amount, Pre-charge Length) Quantity kg (R32) 4.0 Pre Charged To Pipe Length m 30 Installation Data Refrigerant Piping Liquid Line mm Ø9.52 Gas Line Ø15.88 Connection Method Flare Connection Maximum Pipe Length (One Way) m 100 Max vertical height diff. between O.U. and I.U. 50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 Motion Sensor (Optional) LB-KIT2 Demand response (AS4755) Yes Outdoor air temperature (upper, lower limits) Cooling oC -15 to 50 Heating -20 to 20
in 4 offers
Overview Indoor: FDU125VH Outdoor: FDCA125VNX-W Backlit Controller: RC-EXZ3A Specifications CAPACITY 12.5 KW Set FDU125AVNXWVH Indoor FDU125VH Outdoor FDCA125VNX-W Power Source (Outdoor Unit) 1 Phase 240V 50Hz *Operation Data Nominal Capacity Range Cooling T1 kW 12.5 (3.5-14.0) Heating H1 14.0 (2.7-17.0) Heating H2 13.10 Power Consumption Cooling T1 3.49 Heating H1 3.61 Max Power Consumption 7.10 Running Current Cooling T1 A 15.3 Heating H1 15.9 Inrush Current, Maximum Current 5, 28 EER Cooling T1 3.58 COP Heating H1 3.88 Sound Power Level (JS C9612) Outdoor dB(A) 70 Sound Pressure Level (JS C9612) Indoor P-Hi:45 Hi:40 Me:34 Lo:29 Outdoor 54 External Dimensions (HXWXD) Indoor mm 280×1370×740 Outdoor 1300x970x370 Net Weight Indoor Kg 54 Outdoor 97 Supply Air Connection mm 170×1200 Return Air Connection 235×1280 External Static Pressure (Max) Pa 200 Airflow Indoor (Cooling) l/s P-Hi:650 Hi:533 Me:433 Lo:333 Indoor (Heating) Refrigerant (Type, Amount, Pre-charge Length) Quantity kg (R32) 4.0 Pre Charged To Pipe Length m 30 Installation Data Refrigerant Piping Liquid Line mm Ø9.52 Gas Line Ø15.88 Connection Method Flare Connection Maximum Pipe Length (One Way) m 100 Max vertical height diff. between O.U. and I.U. 50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 Motion Sensor (Optional) LB-KIT2 Demand response (AS4755) Yes Outdoor air temperature (upper, lower limits) Cooling oC -15 to 50 Heating -20 to 20
Overview Indoor: FDU125VH Outdoor: FDCA125VNX-W Backlit Controller: RC-EXZ3A Specifications CAPACITY 12.5 KW Set FDU125AVNXWVH Indoor FDU125VH Outdoor FDCA125VNX-W Power Source (Outdoor Unit) 1 Phase 240V 50Hz *Operation Data Nominal Capacity Range Cooling T1 kW 12.5 (3.5-14.0) Heating H1 14.0 (2.7-17.0) Heating H2 13.10 Power Consumption Cooling T1 3.49 Heating H1 3.61 Max Power Consumption 7.10 Running Current Cooling T1 A 15.3 Heating H1 15.9 Inrush Current, Maximum Current 5, 28 EER Cooling T1 3.58 COP Heating H1 3.88 Sound Power Level (JS C9612) Outdoor dB(A) 70 Sound Pressure Level (JS C9612) Indoor P-Hi:45 Hi:40 Me:34 Lo:29 Outdoor 54 External Dimensions (HXWXD) Indoor mm 280×1370×740 Outdoor 1300x970x370 Net Weight Indoor Kg 54 Outdoor 97 Supply Air Connection mm 170×1200 Return Air Connection 235×1280 External Static Pressure (Max) Pa 200 Airflow Indoor (Cooling) l/s P-Hi:650 Hi:533 Me:433 Lo:333 Indoor (Heating) Refrigerant (Type, Amount, Pre-charge Length) Quantity kg (R32) 4.0 Pre Charged To Pipe Length m 30 Installation Data Refrigerant Piping Liquid Line mm Ø9.52 Gas Line Ø15.88 Connection Method Flare Connection Maximum Pipe Length (One Way) m 100 Max vertical height diff. between O.U. and I.U. 50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 Motion Sensor (Optional) LB-KIT2 Demand response (AS4755) Yes Outdoor air temperature (upper, lower limits) Cooling oC -15 to 50 Heating -20 to 20
Last updated at 14/11/2024 15:53:44
Go to store
+ $45.00 delivery
Go to store
Go to store
Affiliate Disclosure: We may receive a small commission for purchases made through this link at no extra cost to you. This helps support our site. Thank you!
+ $99.00 delivery
Go to store
Mitsubishi Heavy Industries 10kW Inverter Ducted System FDUA100VNPWVH
$3,120.00 - $4,198.99
Compare 4 offers
Mitsubishi Heavy Industries 10kW Inverter Ducted System FDU100VNPWVH
$3,135.00 - $4,219.99
Compare 4 offers
CAPACITY | 12.5 KW |
Set | FDU125AVNXWVH |
Controller | RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 |
Motion Sensor (Optional) | LB-KIT2 |
Heating | -20 to 20 |
Updated about 23 hours ago
CAPACITY | 12.5 KW |
Set | FDU125AVNXWVH |
Controller | RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 |
Motion Sensor (Optional) | LB-KIT2 |
Heating | -20 to 20 |